<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>RADON ARTICLES Archives - RadonMarket Academy in English</title>
	<atom:link href="https://www.radonmarketacademy.com/category/1-radon-articles/feed/" rel="self" type="application/rss+xml" />
	<link></link>
	<description>BETA - Radon professional Training Center</description>
	<lastBuildDate>Tue, 20 Sep 2022 14:34:24 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=7.1.2</generator>

<image>
	<url>https://www.radonmarketacademy.com/wp-content/uploads/2020/01/cropped-RadonMarket-Academy_Logo_LQ-32x32.png</url>
	<title>RADON ARTICLES Archives - RadonMarket Academy in English</title>
	<link></link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>RADON-T, FOR RADON RESISTANT NEW CONSTRUCTIONS</title>
		<link>https://www.radonmarketacademy.com/radon-t-for-radon-resistant-new-constructions/</link>
					<comments>https://www.radonmarketacademy.com/radon-t-for-radon-resistant-new-constructions/#respond</comments>
		
		<dc:creator><![CDATA[]]></dc:creator>
		<pubDate>Tue, 20 Sep 2022 14:08:18 +0000</pubDate>
				<category><![CDATA[○ Radon Mitigation]]></category>
		<category><![CDATA[RADON ARTICLES]]></category>
		<category><![CDATA[New Cunstructions]]></category>
		<guid isPermaLink="false">https://www.radonmarketacademy.com/?p=1857</guid>

					<description><![CDATA[<p>The Radon-T is the unique fitting specifically designed as the important first step when installing or roughing in a radon and moisture system during new construction. Radon-T by RadonAway Each Radon-T comes with a kit that includes: ➕ Radon-T – Prepares for Reducing Radon in New Construction (RRNC) systems. ➕ 4 Stakes – Stabilize the [&#8230;]</p>
<p>The post <a href="https://www.radonmarketacademy.com/radon-t-for-radon-resistant-new-constructions/">RADON-T, FOR RADON RESISTANT NEW CONSTRUCTIONS</a> appeared first on <a href="https://www.radonmarketacademy.com">RadonMarket Academy in English</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p style="text-align: justify;">The <a href="https://www.radonmarket.com/33/" target="_blank" rel="noopener">Radon-T</a> is the unique fitting specifically designed as the important first step when installing or roughing in a radon and moisture system during new construction.</p>
<p style="text-align: justify;"><img fetchpriority="high" decoding="async" class="size-medium wp-image-3024 aligncenter" src="https://www.radonmarketacademy.com/it/wp-content/uploads/sites/3/2022/09/Radon-T-kit_RadonAway-1-300x262.jpg" alt="" width="300" height="262" /></p>
<p style="text-align: justify;"><em>Radon-T by RadonAway </em></p>
<p style="text-align: justify;">Each Radon-T comes with a kit that includes:<br />
➕ Radon-T – Prepares for Reducing Radon in New Construction (RRNC) systems.<br />
➕ 4 Stakes – Stabilize the T in preparation for aggregate fill and slab pour.<br />
➕ Vent Pipe Cap – Prevents debris entry and avoids the possibility of mistaking the vent pipe sub for a utility pipe “rough in”.<br />
➕ Set of System Labels – To clearly mark radon system vent pipes.</p>
<p style="text-align: justify;">These instructions provide a quick guide for proper installation.</p>
<p style="text-align: justify;"><strong>✔️PRIOR TO POURING THE SLAB<br />
</strong><strong>Radon-T Installation</strong></p>
<p style="text-align: justify;"><strong>1-</strong> In the location designated for the radon pipe rough-in, position the <a href="https://www.radonmarket.com/33/" target="_blank" rel="noopener">Radon-T</a> on a level dirt surface.</p>
<p style="text-align: justify;"><strong>     a-</strong> For optional 4-way air flow, cut out sides of the <a href="https://www.radonmarket.com/33/" target="_blank" rel="noopener">Radon-T</a> along the indents.</p>
<p style="text-align: justify;"><img decoding="async" class="size-medium wp-image-3025 aligncenter" src="https://www.radonmarketacademy.com/it/wp-content/uploads/sites/3/2022/09/Radon-T-kit_RadonAway-2-300x255.png" alt="" width="300" height="255" /></p>
<p style="text-align: justify;">    <strong> b-</strong> If saddling over an internal perforated pipe loop, cut out a small top section of pipe (approximately 4 ½” x 6”) so that the <a href="https://www.radonmarket.com/33/" target="_blank" rel="noopener">Radon-T</a> fits snugly over the pipe.</p>
<p style="text-align: justify;"><strong>2-</strong> Using the supplied stakes, secure the <a href="https://www.radonmarket.com/33/" target="_blank" rel="noopener">Radon-T</a> to the ground.</p>
<p style="text-align: justify;"><img decoding="async" class="size-medium wp-image-3037 aligncenter" src="https://www.radonmarketacademy.com/it/wp-content/uploads/sites/3/2022/09/Radon-T-kit_RadonAway-3-2-300x247.png" alt="" width="300" height="247" /></p>
<p style="text-align: justify;"><strong>3-</strong> Glue into the <a href="https://www.radonmarket.com/33/" target="_blank" rel="noopener">Radon-T</a> a length of 4” Schedule 40 PVC pipe. (Pipe length should allow it to extend a minimum of 6” above the finished slab.)<br />
<strong>4-</strong> Insert the supplied <a href="https://www.radonmarket.com/33/" target="_blank" rel="noopener">Radon-T</a> Cap into the top of the PVC pipe. Do not glue!</p>
<p style="text-align: justify;"><img loading="lazy" decoding="async" class="size-medium wp-image-3027 aligncenter" src="https://www.radonmarketacademy.com/it/wp-content/uploads/sites/3/2022/09/Radon-T-kit_RadonAway-4-293x300.png" alt="" width="293" height="300" /></p>
<p style="text-align: justify;"><strong>5-</strong> Save the 4 supplied vent pipe labels for future piping.</p>
<p style="text-align: justify;"><strong>Site Preparation<br />
</strong>1- Uniformly spread a layer of clean aggregate at least 4” thick. The aggregate should be sized to pass through a 2” sieve but not through a ¼” sieve. (Where gravel is not available, substitute a 4” layer of sand covered by geotextile drainage matting.)<br />
2- Install vapor barrier (minimum 6 mil or 3 mil cross- laminated) on top of the aggregate. The barrier should cover the entire floor area and seams should have a 12” minimum overlap.</p>
<p style="text-align: justify;"><strong>✔️</strong><strong>AFTER POURING THE SLAB<br />
</strong>1- Fill all large openings in the slab. Seal perimeter and all joints in the concrete, cap sump pit openings. Floor drains should be trapped or routed to daylight with non-perforated pipe.<br />
2- Remove the <a href="https://www.radonmarket.com/33/" target="_blank" rel="noopener">Radon-T</a> cap. Connect and glue PVC riser with appropriate PVC fittings.<br />
3- Route 3” or 4” PVC radon vent pipe through the structure.</p>
<p>&nbsp;</p>
<table style="height: 286px; width: 100%;">
<tbody>
<tr style="height: 286px;">
<td style="text-align: justify; width: 100%; height: 286px;" width="623"><strong><strong><strong>💭</strong></strong></strong><strong style="font-family: inherit; font-size: inherit;">Design reminders</strong></p>
<ul>
<li>Pipe routing should be as straight as possible. Try to avoid 90<sup>o</sup> angles.</li>
<li>Avoid “traps” in the piping so condensation can drain to the soil.</li>
<li>In the attic, leave at least 2 ft clearance around the pipe in all directions, with access to the area for future fan installation.</li>
</ul>
<p>Pipe termination must extend at least 12” above the roof surface and at least 10 ft from doors and other openings (including operable skylights) that are less than 2 ft below the termination point.</td>
</tr>
</tbody>
</table>
<p>&nbsp;</p>
<p style="text-align: justify;">4- Install a wired electrical outlet (120volt AC) next to the anticipated radon fan location.<br />
5- Affix one supplied radon label to the pipe at each level of the structure (e.g., basement, first floor, etc.). Be sure the airflow arrows on the labels point away from the slab.</p>
<p style="text-align: justify;"><em> </em></p>
<p style="text-align: justify;"><em>Source: RadonAway.com</em></p>
<p>The post <a href="https://www.radonmarketacademy.com/radon-t-for-radon-resistant-new-constructions/">RADON-T, FOR RADON RESISTANT NEW CONSTRUCTIONS</a> appeared first on <a href="https://www.radonmarketacademy.com">RadonMarket Academy in English</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://www.radonmarketacademy.com/radon-t-for-radon-resistant-new-constructions/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Why calibrate a measurement instrument?</title>
		<link>https://www.radonmarketacademy.com/why-calibrate-a-measurement-instrument/</link>
					<comments>https://www.radonmarketacademy.com/why-calibrate-a-measurement-instrument/#respond</comments>
		
		<dc:creator><![CDATA[]]></dc:creator>
		<pubDate>Mon, 13 Jun 2022 13:38:29 +0000</pubDate>
				<category><![CDATA[○ Radon Short Articles]]></category>
		<category><![CDATA[RADON ARTICLES]]></category>
		<guid isPermaLink="false">https://www.radonmarketacademy.com/?p=1843</guid>

					<description><![CDATA[<p>RADON IN PILLOLE: WHY CALIBRATE A MEASUREMENT INSTRUMENT?  📽️ In this video, we will answer this common question: ﻿ 🗯️ Perché tarare uno strumento di misura? Calibration: ✅ calibration has the purpose of defining the metrological characteristics of a measuring instrument; ✅ verifies the accuracy and precision of the instrument and determines the uncertainty; ✅ [&#8230;]</p>
<p>The post <a href="https://www.radonmarketacademy.com/why-calibrate-a-measurement-instrument/">Why calibrate a measurement instrument?</a> appeared first on <a href="https://www.radonmarketacademy.com">RadonMarket Academy in English</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p style="text-align: justify;"><span style="font-size: 18pt; font-family: 'arial black', sans-serif;"><strong><a href="https://www.radonmarketacademy.com/it/category/articoli-sul-radon/radon-in-pillole/"><img loading="lazy" decoding="async" class="alignnone wp-image-2086" src="https://www.radonmarketacademy.com/it/wp-content/uploads/sites/3/2020/11/Radon-in-Pillole-300x130.png" alt="" width="50" height="22" /></a></strong></span></p>
<p style="text-align: justify;"><span style="font-size: 18pt; font-family: 'arial black', sans-serif;"><strong><span style="font-size: 14pt;">RADON IN PILLOLE: WHY CALIBRATE A MEASUREMENT INSTRUMENT?</span></strong></span></p>
<p style="text-align: justify;"><span class="style-scope yt-formatted-string" dir="auto"> 📽️ In this video, we will answer this common question:<br />
</span></p>
<p style="text-align: justify;"><span class="style-scope yt-formatted-string" dir="auto"><iframe src="//www.youtube.com/embed/VZCrQt_hauA" width="560" height="314" allowfullscreen="allowfullscreen" data-mce-fragment="1"><span data-mce-type="bookmark" style="display: inline-block; width: 0px; overflow: hidden; line-height: 0;" class="mce_SELRES_start">﻿</span></iframe><br />
</span><span class="style-scope yt-formatted-string" dir="auto"><strong>🗯️ Perché tarare uno strumento di misura?</strong></span></p>
<p style="text-align: justify;"><strong>Calibration: </strong><br />
✅ calibration has the purpose of defining the metrological characteristics of a measuring instrument;<br />
✅ verifies the accuracy and precision of the instrument and determines the uncertainty;<br />
✅ maintains the state of confidence in the measurement process;<br />
✅ it is a requirement foreseen by the technical standards;<br />
✅ with the calibration, a &#8220;dimensionless&#8221; calibration factor is determined, which can be used to correct the instrument&#8217;s response and make it more accurate.</p>
<p style="text-align: justify;"><strong>Calibration: how often?<br />
</strong>Calibration is a &#8220;snapshot&#8221; of the instrument&#8217;s characteristics at the time of the calibration itself. However, it offers no guarantees once the instrument has left the calibration center.<br />
This is why it is essential to calibrate a measurement instrument periodically: we cannot know when the instrument could lose its calibration. The longer we wait, the greater the number of measurements carried out with an instrument that no longer works correctly.</p>
<p style="text-align: justify;"><span class="style-scope yt-formatted-string" dir="auto" style="color: #00a693;"><strong>We at RadonMarket recommend calibration at least annually.  </strong> </span></p>
<p style="text-align: justify;"><span class="style-scope yt-formatted-string" dir="auto"><strong>How are the instruments for measuring radon calibrated?</strong><br />
The IEC 61577 standard defines the requirements for calibration systems and thus helps us answer this question.<br />
Calibrating radon instruments involves the use of a &#8220;STAR&#8221; (System for Test Atmospheres with Radon) chamber as follows:<br />
✅ a sealed chamber where to place the instruments to be calibrated and the reference instrument;<br />
✅ a certified radon source;<br />
✅ a control system for the introduction of radon inside the calibration chamber;<br />
✅ a system for monitoring internal environmental parameters;<br />
✅ an exhaust system compliant with regulatory requirements. </span></p>
<p><strong>Follow us to learn more</strong><span class="style-scope yt-formatted-string" dir="auto"><br />
<strong>Radon professional Training Center</strong><br />
</span></p>
<p style="text-align: justify;"><a class="yt-simple-endpoint style-scope yt-formatted-string" dir="auto" spellcheck="false" href="https://www.youtube.com/hashtag/radon">#Radon</a> <a class="yt-simple-endpoint style-scope yt-formatted-string" dir="auto" spellcheck="false" href="https://www.youtube.com/hashtag/gasradon">#GasRadon</a> <a class="yt-simple-endpoint style-scope yt-formatted-string" dir="auto" spellcheck="false" href="https://www.youtube.com/hashtag/radongas">#RadonGas</a> <a class="yt-simple-endpoint style-scope yt-formatted-string" dir="auto" spellcheck="false" href="https://www.youtube.com/hashtag/radoninstruments">#RadonInstruments</a> <a class="yt-simple-endpoint style-scope yt-formatted-string" dir="auto" spellcheck="false" href="https://www.youtube.com/hashtag/risanamento">#Risanamento</a> <a class="yt-simple-endpoint style-scope yt-formatted-string" dir="auto" spellcheck="false" href="https://www.youtube.com/hashtag/risanamentoradon">#RisanamentoRadon</a> <a class="yt-simple-endpoint style-scope yt-formatted-string" dir="auto" spellcheck="false" href="https://www.youtube.com/hashtag/mitigation">#Mitigation</a> <a class="yt-simple-endpoint style-scope yt-formatted-string" dir="auto" spellcheck="false" href="https://www.youtube.com/hashtag/radonmitigation">#RadonMitigation</a> <a class="yt-simple-endpoint style-scope yt-formatted-string" dir="auto" spellcheck="false" href="https://www.youtube.com/hashtag/misuraradon">#MisuraRadon</a> <a class="yt-simple-endpoint style-scope yt-formatted-string" dir="auto" spellcheck="false" href="https://www.youtube.com/hashtag/radonmeasurements">#RadonMeasurements</a> <a class="yt-simple-endpoint style-scope yt-formatted-string" dir="auto" spellcheck="false" href="https://www.youtube.com/hashtag/radonmarket">#RadonMarket</a> <a class="yt-simple-endpoint style-scope yt-formatted-string" dir="auto" spellcheck="false" href="https://www.youtube.com/hashtag/swemstudio">#SwemStudio</a> <a class="yt-simple-endpoint style-scope yt-formatted-string" dir="auto" spellcheck="false" href="https://www.youtube.com/hashtag/radonmarketacademy">#RadonMarketAcademy</a> <a class="yt-simple-endpoint style-scope yt-formatted-string" dir="auto" spellcheck="false" href="https://www.youtube.com/hashtag/radoninpillole">#RadoninPillole</a> <a class="yt-simple-endpoint style-scope yt-formatted-string" dir="auto" spellcheck="false" href="https://www.youtube.com/hashtag/misurazioneradon">#Misurazioneradon</a> <a class="yt-simple-endpoint style-scope yt-formatted-string" dir="auto" spellcheck="false" href="https://www.youtube.com/hashtag/ambient">#Ambient</a> <a class="yt-simple-endpoint style-scope yt-formatted-string" dir="auto" spellcheck="false" href="https://www.youtube.com/hashtag/salute">#Salute</a> <a class="yt-simple-endpoint style-scope yt-formatted-string" dir="auto" spellcheck="false" href="https://www.youtube.com/hashtag/taratura">#Taratura</a> <a class="yt-simple-endpoint style-scope yt-formatted-string" dir="auto" spellcheck="false" href="https://www.youtube.com/hashtag/calibration">#Calibration</a> <a class="yt-simple-endpoint style-scope yt-formatted-string" dir="auto" spellcheck="false" href="https://www.youtube.com/hashtag/taraturaradon">#TaraturaRadon</a></p>
<hr />
<p style="text-align: justify;"><a href="https://www.radonmarket.com/it/radonmarket-mag/" target="_blank" rel="noopener noreferrer"><img loading="lazy" decoding="async" class="alignnone wp-image-1990 size-medium" src="https://www.radonmarketacademy.com/it/wp-content/uploads/sites/3/2020/10/RadonMarket-Mag-Logo-300x53.png" alt="" width="300" height="53" /></a></p>
<p style="text-align: justify;"><span style="color: #808080;"><em>RadonMarket Academy, Centro di Formazione Professionale del Radon</em></span></p>
<p>The post <a href="https://www.radonmarketacademy.com/why-calibrate-a-measurement-instrument/">Why calibrate a measurement instrument?</a> appeared first on <a href="https://www.radonmarketacademy.com">RadonMarket Academy in English</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://www.radonmarketacademy.com/why-calibrate-a-measurement-instrument/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>WHAT IS A &#8220;SAFE&#8221; LEVEL OF INDOOR RADON GAS?</title>
		<link>https://www.radonmarketacademy.com/what-is-a-safe-level-of-indoor-radon-gas/</link>
					<comments>https://www.radonmarketacademy.com/what-is-a-safe-level-of-indoor-radon-gas/#respond</comments>
		
		<dc:creator><![CDATA[]]></dc:creator>
		<pubDate>Thu, 31 Mar 2022 14:35:28 +0000</pubDate>
				<category><![CDATA[○ Radon Short Articles]]></category>
		<category><![CDATA[RADON ARTICLES]]></category>
		<guid isPermaLink="false">https://www.radonmarketacademy.com/?p=1833</guid>

					<description><![CDATA[<p>RADON IN PILLOLE: WHAT IS A &#8220;SAFE&#8221; LEVEL OF INDOOR RADON GAS?  📽️ In this video, we will answer this common question: ﻿ The short answer is the &#8220;safe&#8221; level of radon exposure is no radon at all. Any radon exposure carries some risk. 🗯️So does it mean that we should have 0 Radon at [&#8230;]</p>
<p>The post <a href="https://www.radonmarketacademy.com/what-is-a-safe-level-of-indoor-radon-gas/">WHAT IS A &#8220;SAFE&#8221; LEVEL OF INDOOR RADON GAS?</a> appeared first on <a href="https://www.radonmarketacademy.com">RadonMarket Academy in English</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p style="text-align: justify;"><span style="font-size: 18pt; font-family: 'arial black', sans-serif;"><strong><a href="https://www.radonmarketacademy.com/it/category/articoli-sul-radon/radon-in-pillole/"><img loading="lazy" decoding="async" class="alignnone wp-image-2086" src="https://www.radonmarketacademy.com/it/wp-content/uploads/sites/3/2020/11/Radon-in-Pillole-300x130.png" alt="" width="50" height="22" /></a></strong></span></p>
<p style="text-align: justify;"><span style="font-size: 18pt; font-family: 'arial black', sans-serif;"><strong><span style="font-size: 14pt;">RADON IN PILLOLE: WHAT IS A &#8220;SAFE&#8221; LEVEL OF INDOOR RADON GAS?</span></strong></span></p>
<p style="text-align: justify;"><span class="style-scope yt-formatted-string" dir="auto"> 📽️ In this video, we will answer this common question:<br />
</span></p>
<p style="text-align: justify;"><span class="style-scope yt-formatted-string" dir="auto"><iframe src="//www.youtube.com/embed/MMA2sobZ2JQ" width="560" height="314" allowfullscreen="allowfullscreen" data-mce-fragment="1"><span data-mce-type="bookmark" style="display: inline-block; width: 0px; overflow: hidden; line-height: 0;" class="mce_SELRES_start">﻿</span></iframe><br />
The short answer is the &#8220;safe&#8221; level of radon exposure is no radon at all. Any radon exposure carries some risk.<br />
<strong>🗯️So does it mean that we should have 0 Radon at our home to be safe? The answer is not that simple! Let&#8217;s see why!</strong><br />
Even outside our homes, we could expose ourselves to some level of radon. Roughly 0.4 pCi/L of radon is normally found in the outside air. So, the optimistic goal should be to reduce indoor Radon levels to no more than outdoor levels. However, this goal is not yet technologically achievable for all homes.</span></p>
<p style="text-align: justify;"><span class="style-scope yt-formatted-string" dir="auto">For these reasons, similarly to what happens for other risks, the concept of acceptable risk is applied to exposure to radon, which leads to the definition of reference levels.<br />
The reference level also depends on the organization that defines it or on the regulations applied in the different countries.<br />
</span></p>
<p style="text-align: justify;"><span class="style-scope yt-formatted-string" dir="auto">As an example, the reference level is equal to:<br />
✅WHO (World Health Organization) recommends: 100 Bq/m<sup>3</sup><br />
✅ EPA (U.S. Environmental Protection Agency) recommends: 150 Bq/m<sup>3</sup><br />
✅Italy and many other EU countries recommend: 300 Bq/m<sup>3</sup></span></p>
<p style="text-align: justify;"><span class="style-scope yt-formatted-string" dir="auto">If you find that you have high indoor Radon levels, there are ways to fix it. Even very high levels can be reduced to acceptable levels. On average, Radon levels in many homes can be reduced to 2 pCi/L or less. </span></p>
<p style="text-align: justify;"><span class="style-scope yt-formatted-string" dir="auto"><strong>But the first step is to test your home! </strong></span><strong>Go to <a href="https://www.radonmarket.com/" target="_blank" rel="noopener">RadonMarket.com</a> and find the right tool for you.</strong></p>
<p style="text-align: justify;"><strong>Follow us to learn more</strong></p>
<p style="text-align: justify;"><span class="style-scope yt-formatted-string" dir="auto"> </span><a class="yt-simple-endpoint style-scope yt-formatted-string" dir="auto" spellcheck="false" href="https://www.youtube.com/hashtag/radon">#Radon</a> <a class="yt-simple-endpoint style-scope yt-formatted-string" dir="auto" spellcheck="false" href="https://www.youtube.com/hashtag/gasradon">#GasRadon</a> <a class="yt-simple-endpoint style-scope yt-formatted-string" dir="auto" spellcheck="false" href="https://www.youtube.com/hashtag/radongas">#RadonGas</a> <a class="yt-simple-endpoint style-scope yt-formatted-string" dir="auto" spellcheck="false" href="https://www.youtube.com/hashtag/radoninstruments">#RadonInstruments</a> <a class="yt-simple-endpoint style-scope yt-formatted-string" dir="auto" spellcheck="false" href="https://www.youtube.com/hashtag/risanamento">#Risanamento</a> <a class="yt-simple-endpoint style-scope yt-formatted-string" dir="auto" spellcheck="false" href="https://www.youtube.com/hashtag/risanamentoradon">#RisanamentoRadon</a> <a class="yt-simple-endpoint style-scope yt-formatted-string" dir="auto" spellcheck="false" href="https://www.youtube.com/hashtag/mitigation">#Mitigation</a> <a class="yt-simple-endpoint style-scope yt-formatted-string" dir="auto" spellcheck="false" href="https://www.youtube.com/hashtag/radonmitigation">#RadonMitigation</a> <a class="yt-simple-endpoint style-scope yt-formatted-string" dir="auto" spellcheck="false" href="https://www.youtube.com/hashtag/misuraradon">#MisuraRadon</a> <a class="yt-simple-endpoint style-scope yt-formatted-string" dir="auto" spellcheck="false" href="https://www.youtube.com/hashtag/radonmeasurements">#RadonMeasurements</a> <a class="yt-simple-endpoint style-scope yt-formatted-string" dir="auto" spellcheck="false" href="https://www.youtube.com/hashtag/radonmarket">#RadonMarket</a> <a class="yt-simple-endpoint style-scope yt-formatted-string" dir="auto" spellcheck="false" href="https://www.youtube.com/hashtag/swemstudio">#SwemStudio</a> <a class="yt-simple-endpoint style-scope yt-formatted-string" dir="auto" spellcheck="false" href="https://www.youtube.com/hashtag/radonmarketacademy">#RadonMarketAcademy</a> <a class="yt-simple-endpoint style-scope yt-formatted-string" dir="auto" spellcheck="false" href="https://www.youtube.com/hashtag/radoninpillole">#RadoninPillole</a> <a class="yt-simple-endpoint style-scope yt-formatted-string" dir="auto" spellcheck="false" href="https://www.youtube.com/hashtag/misurazioneradon">#Misurazioneradon</a> <a class="yt-simple-endpoint style-scope yt-formatted-string" dir="auto" spellcheck="false" href="https://www.youtube.com/hashtag/ambient">#Ambient</a> <a class="yt-simple-endpoint style-scope yt-formatted-string" dir="auto" spellcheck="false" href="https://www.youtube.com/hashtag/salute">#Salute</a></p>
<hr />
<p style="text-align: justify;"><a href="https://www.radonmarket.com/it/radonmarket-mag/" target="_blank" rel="noopener noreferrer"><img loading="lazy" decoding="async" class="alignnone wp-image-1990 size-medium" src="https://www.radonmarketacademy.com/it/wp-content/uploads/sites/3/2020/10/RadonMarket-Mag-Logo-300x53.png" alt="" width="300" height="53" /></a></p>
<p style="text-align: justify;"><span style="color: #808080;"><em>RadonMarket Academy, Centro di Formazione Professionale del Radon</em></span></p>
<p>The post <a href="https://www.radonmarketacademy.com/what-is-a-safe-level-of-indoor-radon-gas/">WHAT IS A &#8220;SAFE&#8221; LEVEL OF INDOOR RADON GAS?</a> appeared first on <a href="https://www.radonmarketacademy.com">RadonMarket Academy in English</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://www.radonmarketacademy.com/what-is-a-safe-level-of-indoor-radon-gas/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>RADON MEASUREMENT QUALITY: PRECISION, BIAS, AND ACCURACY</title>
		<link>https://www.radonmarketacademy.com/radon-measurement-quality-precision-bias-and-accuracy/</link>
					<comments>https://www.radonmarketacademy.com/radon-measurement-quality-precision-bias-and-accuracy/#respond</comments>
		
		<dc:creator><![CDATA[]]></dc:creator>
		<pubDate>Fri, 04 Mar 2022 14:28:35 +0000</pubDate>
				<category><![CDATA[○ Radon Instruments]]></category>
		<category><![CDATA[RADON ARTICLES]]></category>
		<guid isPermaLink="false">https://www.radonmarketacademy.com/?p=1821</guid>

					<description><![CDATA[<p>Reza Hosseini, PhD &#8211; Managing Director at RadonMarket, R&#38;D Manager &#38; NRPP MFM Certified Radon Professional at Niton srl Like any other measurement activity, Radon gas measurement needs a quality program to evaluate and assess the test results. A Radon quality measurement program consists of Quality Control (QC) and  Quality Assurance (QA) plans. In a [&#8230;]</p>
<p>The post <a href="https://www.radonmarketacademy.com/radon-measurement-quality-precision-bias-and-accuracy/">RADON MEASUREMENT QUALITY: PRECISION, BIAS, AND ACCURACY</a> appeared first on <a href="https://www.radonmarketacademy.com">RadonMarket Academy in English</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p style="text-align: justify;"><a href="https://www.radonmarket.com/it/radonmarket-mag/" target="_blank" rel="noopener noreferrer"><img loading="lazy" decoding="async" class="alignnone wp-image-1990 size-medium" src="https://www.radonmarketacademy.com/it/wp-content/uploads/sites/3/2020/10/RadonMarket-Mag-Logo-300x53.png" alt="" width="300" height="53" /></a><br />
<span style="color: #808080;"><em>Reza Hosseini, PhD &#8211; Managing Director at RadonMarket, R&amp;D Manager &amp; NRPP MFM Certified Radon Professional at Niton srl</em></span></p>
<p style="text-align: justify;">Like any other measurement activity, Radon gas measurement needs a quality program to evaluate and assess the test results. A Radon quality measurement program consists of Quality Control (QC) and  Quality Assurance (QA) plans. In a nutshell:</p>
<p style="text-align: justify;">✅ The QC plans are the measures taken to increase confidence in the results.<br />
✅ Then, the QA plans ensure that the QC plans are being done correctly and in a timely manner.</p>
<p style="text-align: justify;">QC plans include duplicates, fields blanks, spikes, calibration, background checks, and source checks. And QA plans include creating control charts, keeping the records, and inspecting procedures. Before talking about these interesting topics 🤩, we should have a very good understanding of three concepts: <strong>PRECISION, BIAS, AND ACCURACY</strong></p>
<p><img loading="lazy" decoding="async" class="aligncenter wp-image-1822 size-large" src="https://www.radonmarketacademy.com/wp-content/uploads/2022/03/Radon-Measurement-Quality_QC_QA_RadonMarket-1024x559.png" alt="" width="1024" height="559" srcset="https://www.radonmarketacademy.com/wp-content/uploads/2022/03/Radon-Measurement-Quality_QC_QA_RadonMarket-1024x559.png 1024w, https://www.radonmarketacademy.com/wp-content/uploads/2022/03/Radon-Measurement-Quality_QC_QA_RadonMarket-300x164.png 300w, https://www.radonmarketacademy.com/wp-content/uploads/2022/03/Radon-Measurement-Quality_QC_QA_RadonMarket-768x419.png 768w, https://www.radonmarketacademy.com/wp-content/uploads/2022/03/Radon-Measurement-Quality_QC_QA_RadonMarket-1536x839.png 1536w, https://www.radonmarketacademy.com/wp-content/uploads/2022/03/Radon-Measurement-Quality_QC_QA_RadonMarket.png 2000w" sizes="(max-width: 1024px) 100vw, 1024px" /></p>
<p style="text-align: center;"><em>Radon Measurement Quality- Precision, Bias, Accuracy</em></p>
<p style="text-align: justify;"><strong>✔️ </strong><strong>PRECISION</strong></p>
<p style="text-align: justify;">Consider performing multiple Radon measurements simultaneously inside a building, with the same condition and the same type of instrument. After comparing their results, the measurement is Precise if the results are close together. On the other hand, if the results are far away from each other, the measurement has poor precision.</p>
<p style="text-align: justify;">Measurement precision should be controlled as part of the Radon QC plans. An example of this control is to perform &#8220;Duplicates<sup>📣</sup>. &#8220;</p>
<table width="620">
<tbody>
<tr>
<td width="620">📣 Duplicates are two simultaneous measurements with the same device. The number of them should be equal to 10% of measured locations (per device type) and for a maximum of 50 duplicates per month.</td>
</tr>
</tbody>
</table>
<p style="text-align: justify;">Now let&#8217;s see why having good Precision is essential but not enough. When testing a building for Radon, the Radon level of the building is unknown. Therefore even if the multiple results are close together (good Precision), they could be far from the actual Radon concentration or the target level. In other words, there could be good Precision but poor &#8220;Bias.&#8221;</p>
<p style="text-align: justify;"><img loading="lazy" decoding="async" class="aligncenter wp-image-1823 size-large" src="https://www.radonmarketacademy.com/wp-content/uploads/2022/03/Radon-Measurement-Quality_QC_QA_Precision_2_RadonMarket-1024x559.png" alt="" width="1024" height="559" srcset="https://www.radonmarketacademy.com/wp-content/uploads/2022/03/Radon-Measurement-Quality_QC_QA_Precision_2_RadonMarket-1024x559.png 1024w, https://www.radonmarketacademy.com/wp-content/uploads/2022/03/Radon-Measurement-Quality_QC_QA_Precision_2_RadonMarket-300x164.png 300w, https://www.radonmarketacademy.com/wp-content/uploads/2022/03/Radon-Measurement-Quality_QC_QA_Precision_2_RadonMarket-768x419.png 768w, https://www.radonmarketacademy.com/wp-content/uploads/2022/03/Radon-Measurement-Quality_QC_QA_Precision_2_RadonMarket-1536x839.png 1536w, https://www.radonmarketacademy.com/wp-content/uploads/2022/03/Radon-Measurement-Quality_QC_QA_Precision_2_RadonMarket.png 2000w" sizes="(max-width: 1024px) 100vw, 1024px" /></p>
<p style="text-align: center;"><em>Radon Measurement Quality, Precise measurement with poor Bias</em></p>
<p>&nbsp;</p>
<p style="text-align: justify;"><strong> </strong></p>
<p style="text-align: justify;"><strong>✔️ </strong><strong>BIAS</strong></p>
<p style="text-align: justify;">The Bias could be associated with improperly storing the detectors or due to collecting Radon by detectors during their shipment, or it could even be a laboratory problem<sup>🔔</sup>.</p>
<table width="620">
<tbody>
<tr>
<td width="620">🔔 Bias in Radon measurement is typically on a positive side, and it indicates higher Radon levels compare to the actual values.</td>
</tr>
</tbody>
</table>
<p style="text-align: justify;">Bias shows how far the result is from the target value. But how is it possible to determine the Bias when the target value is unknown? The solution is to define a known target value equal to zero! It is achievable by measuring the Radon concentration from not exposed detectors and calculating how much the results are off from zero. This way of calculating the Bias in the Radon QC plans is called &#8220;Field blanks<sup>📣</sup>.&#8221;</p>
<table width="620">
<tbody>
<tr>
<td width="620">📣 Field blanks are not exposed but evaluated devices. The number of them should be equal to 5% of the measured locations (per device type) and for a maximum number of 25 field blanks per month. The results should be close to 0 Bq/m<sup>3</sup>.</td>
</tr>
</tbody>
</table>
<p style="text-align: justify;">Having a good bias does not indicate that the measurement is precise too. Here is where &#8220;Accuracy&#8221; comes into the scene. An accurate measurement is Precise with good Bias.</p>
<p style="text-align: center;"><strong><img loading="lazy" decoding="async" class="aligncenter wp-image-1824 size-large" src="https://www.radonmarketacademy.com/wp-content/uploads/2022/03/Radon-Measurement-Quality_QC_QA_Bias_2_RadonMarket-1024x559.png" alt="" width="1024" height="559" srcset="https://www.radonmarketacademy.com/wp-content/uploads/2022/03/Radon-Measurement-Quality_QC_QA_Bias_2_RadonMarket-1024x559.png 1024w, https://www.radonmarketacademy.com/wp-content/uploads/2022/03/Radon-Measurement-Quality_QC_QA_Bias_2_RadonMarket-300x164.png 300w, https://www.radonmarketacademy.com/wp-content/uploads/2022/03/Radon-Measurement-Quality_QC_QA_Bias_2_RadonMarket-768x419.png 768w, https://www.radonmarketacademy.com/wp-content/uploads/2022/03/Radon-Measurement-Quality_QC_QA_Bias_2_RadonMarket-1536x839.png 1536w, https://www.radonmarketacademy.com/wp-content/uploads/2022/03/Radon-Measurement-Quality_QC_QA_Bias_2_RadonMarket.png 2000w" sizes="(max-width: 1024px) 100vw, 1024px" /><br />
</strong><em>Radon Measurement Quality, not Precise measurement with good Bias</em></p>
<p style="text-align: justify;"><strong> </strong></p>
<p style="text-align: justify;"><strong>✔️ </strong><strong>ACCURACY</strong></p>
<p style="text-align: justify;">Accuracy is mainly a function of Bias (how far the measurement results are from the target value). The only way to verify the Accuracy is by exposing some sample detectors to a known Radon environment. These sample detectors are called &#8220;Spikes<sup>📣</sup>,&#8221; and they should be part of the QC plans. Spike samples are sent to a Radon chamber (it could be a secondary Radon chamber) and exposed to predefined Radon concentration. Then the sample&#8217;s measured values are compared with the Radon chamber declared concentration to determine the measurement&#8217;s Accuracy.</p>
<table width="620">
<tbody>
<tr>
<td width="620">📣 Spikes are devices exposed to known Radon environment. The number of spike samples should be equal to 3% of the measured locations (per device type) and for a maximum of 6 per month and a minimum of 3 spikes per year.</td>
</tr>
</tbody>
</table>
<p style="text-align: justify;"><img loading="lazy" decoding="async" class="aligncenter wp-image-1825 size-large" src="https://www.radonmarketacademy.com/wp-content/uploads/2022/03/Radon-Measurement-Quality_QC_QA_Accuracy_2_RadonMarket-1024x559.png" alt="" width="1024" height="559" srcset="https://www.radonmarketacademy.com/wp-content/uploads/2022/03/Radon-Measurement-Quality_QC_QA_Accuracy_2_RadonMarket-1024x559.png 1024w, https://www.radonmarketacademy.com/wp-content/uploads/2022/03/Radon-Measurement-Quality_QC_QA_Accuracy_2_RadonMarket-300x164.png 300w, https://www.radonmarketacademy.com/wp-content/uploads/2022/03/Radon-Measurement-Quality_QC_QA_Accuracy_2_RadonMarket-768x419.png 768w, https://www.radonmarketacademy.com/wp-content/uploads/2022/03/Radon-Measurement-Quality_QC_QA_Accuracy_2_RadonMarket-1536x839.png 1536w, https://www.radonmarketacademy.com/wp-content/uploads/2022/03/Radon-Measurement-Quality_QC_QA_Accuracy_2_RadonMarket.png 2000w" sizes="(max-width: 1024px) 100vw, 1024px" /></p>
<p style="text-align: center;"><em>Radon Measurement Quality, Precise measurement with good Bias, Accurate measurement</em></p>
<p style="text-align: justify;">By understanding these three essential concepts, we are now able to go into detail and talk about Quality Controls (QC) and Quality Assurance (QA) plans. So do not miss the future numbers of RadonMarket Magazine.</p>
<p>The post <a href="https://www.radonmarketacademy.com/radon-measurement-quality-precision-bias-and-accuracy/">RADON MEASUREMENT QUALITY: PRECISION, BIAS, AND ACCURACY</a> appeared first on <a href="https://www.radonmarketacademy.com">RadonMarket Academy in English</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://www.radonmarketacademy.com/radon-measurement-quality-precision-bias-and-accuracy/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>DO RADON LEVELS INCREASE WITH THE AGE OF A BUILDING?</title>
		<link>https://www.radonmarketacademy.com/do-radon-levels-increase-with-the-age-of-a-building/</link>
					<comments>https://www.radonmarketacademy.com/do-radon-levels-increase-with-the-age-of-a-building/#respond</comments>
		
		<dc:creator><![CDATA[]]></dc:creator>
		<pubDate>Tue, 15 Feb 2022 10:51:49 +0000</pubDate>
				<category><![CDATA[○ Radon Short Articles]]></category>
		<category><![CDATA[RADON ARTICLES]]></category>
		<guid isPermaLink="false">https://www.radonmarketacademy.com/?p=1814</guid>

					<description><![CDATA[<p>RADON IN PILLOLE: DO RADON LEVELS INCREASE WITH THE AGE OF A BUILDING?  📽️ In this video, we will answer this common question: 🗯️Do radon levels increase with the age of a building?❓ No. Actually, there is no relation between the age of a building and its Radon level. Let&#8217;s examine factors that influence the [&#8230;]</p>
<p>The post <a href="https://www.radonmarketacademy.com/do-radon-levels-increase-with-the-age-of-a-building/">DO RADON LEVELS INCREASE WITH THE AGE OF A BUILDING?</a> appeared first on <a href="https://www.radonmarketacademy.com">RadonMarket Academy in English</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><span style="font-size: 18pt; font-family: 'arial black', sans-serif;"><strong><a href="https://www.radonmarketacademy.com/it/category/articoli-sul-radon/radon-in-pillole/"><img loading="lazy" decoding="async" class="alignnone wp-image-2086" src="https://www.radonmarketacademy.com/it/wp-content/uploads/sites/3/2020/11/Radon-in-Pillole-300x130.png" alt="" width="50" height="22" /></a></strong></span></p>
<p><span style="font-size: 18pt; font-family: 'arial black', sans-serif;"><strong><span style="font-size: 14pt;">RADON IN PILLOLE: DO RADON LEVELS INCREASE WITH THE AGE OF A BUILDING?</span></strong></span></p>
<p><span class="style-scope yt-formatted-string" dir="auto"> 📽️ In this video, we will answer this common question:<br />
</span></p>
<p><span class="style-scope yt-formatted-string" dir="auto"><iframe src="//www.youtube.com/embed/PAo1DMv5gso" width="560" height="314" allowfullscreen="allowfullscreen" data-mce-fragment="1"></iframe><br />
<strong>🗯️Do radon levels increase with the age of a building?❓ </strong><br />
No. Actually, there is no relation between the age of a building and its Radon level. Let&#8217;s examine factors that influence the Radon level to understand it better.<br />
<strong>1️⃣ Source:</strong><br />
&#8211; This is the amount of Uranium238 or Radium226 present in the soil underneath the building.<br />
&#8211; No matter if the building is old or new, No Source means No Radon!<br />
<strong>2️⃣ Driving force:</strong><br />
&#8211; This mainly depends on the inside and outside temperature differences.<br />
&#8211; Colder outside means a stronger force that pushes Radon laden air into the building.<br />
</span><strong>3️⃣ Pathway and openings:</strong><br />
&#8211; Radon needs a path to enter the building. Tiny cracks would be enough.<br />
&#8211; And you know what? Sooner or later, Radon will find this path even in a tight new building.<br />
<strong>4️⃣ Ventilation rate:</strong><br />
&#8211; This is the rate of air exchange to the outside.<br />
&#8211; Air exchange can lower the Radon level by dilution. Older buildings may even have higher air exchange rates.</p>
<p><strong>So no matter the age of the building. The only way to understand the Radon level is by measuring it!<br />
Buy your Radon Test kit now at <a href="https://www.radonmarket.com/" target="_blank" rel="noopener">RadonMarket.com</a></strong></p>
<p><strong>Follow us to learn more</strong></p>
<p><span class="style-scope yt-formatted-string" dir="auto"> </span><a class="yt-simple-endpoint style-scope yt-formatted-string" dir="auto" spellcheck="false" href="https://www.youtube.com/hashtag/radon">#Radon</a> <a class="yt-simple-endpoint style-scope yt-formatted-string" dir="auto" spellcheck="false" href="https://www.youtube.com/hashtag/gasradon">#GasRadon</a> <a class="yt-simple-endpoint style-scope yt-formatted-string" dir="auto" spellcheck="false" href="https://www.youtube.com/hashtag/radongas">#RadonGas</a> <a class="yt-simple-endpoint style-scope yt-formatted-string" dir="auto" spellcheck="false" href="https://www.youtube.com/hashtag/radoninstruments">#RadonInstruments</a> <a class="yt-simple-endpoint style-scope yt-formatted-string" dir="auto" spellcheck="false" href="https://www.youtube.com/hashtag/risanamento">#Risanamento</a> <a class="yt-simple-endpoint style-scope yt-formatted-string" dir="auto" spellcheck="false" href="https://www.youtube.com/hashtag/risanamentoradon">#RisanamentoRadon</a> <a class="yt-simple-endpoint style-scope yt-formatted-string" dir="auto" spellcheck="false" href="https://www.youtube.com/hashtag/mitigation">#Mitigation</a> <a class="yt-simple-endpoint style-scope yt-formatted-string" dir="auto" spellcheck="false" href="https://www.youtube.com/hashtag/radonmitigation">#RadonMitigation</a> <a class="yt-simple-endpoint style-scope yt-formatted-string" dir="auto" spellcheck="false" href="https://www.youtube.com/hashtag/misuraradon">#MisuraRadon</a> <a class="yt-simple-endpoint style-scope yt-formatted-string" dir="auto" spellcheck="false" href="https://www.youtube.com/hashtag/radonmeasurements">#RadonMeasurements</a> <a class="yt-simple-endpoint style-scope yt-formatted-string" dir="auto" spellcheck="false" href="https://www.youtube.com/hashtag/radonmarket">#RadonMarket</a> <a class="yt-simple-endpoint style-scope yt-formatted-string" dir="auto" spellcheck="false" href="https://www.youtube.com/hashtag/swemstudio">#SwemStudio</a> <a class="yt-simple-endpoint style-scope yt-formatted-string" dir="auto" spellcheck="false" href="https://www.youtube.com/hashtag/radonmarketacademy">#RadonMarketAcademy</a> <a class="yt-simple-endpoint style-scope yt-formatted-string" dir="auto" spellcheck="false" href="https://www.youtube.com/hashtag/radoninpillole">#RadoninPillole</a> <a class="yt-simple-endpoint style-scope yt-formatted-string" dir="auto" spellcheck="false" href="https://www.youtube.com/hashtag/misurazioneradon">#Misurazioneradon</a> <a class="yt-simple-endpoint style-scope yt-formatted-string" dir="auto" spellcheck="false" href="https://www.youtube.com/hashtag/ambient">#Ambient</a> <a class="yt-simple-endpoint style-scope yt-formatted-string" dir="auto" spellcheck="false" href="https://www.youtube.com/hashtag/salute">#Salute</a></p>
<hr />
<p>&nbsp;</p>
<p style="text-align: justify;"><a href="https://www.radonmarket.com/it/radonmarket-mag/" target="_blank" rel="noopener noreferrer"><img loading="lazy" decoding="async" class="alignnone wp-image-1990 size-medium" src="https://www.radonmarketacademy.com/it/wp-content/uploads/sites/3/2020/10/RadonMarket-Mag-Logo-300x53.png" alt="" width="300" height="53" /></a></p>
<p style="text-align: justify;"><span style="color: #808080;"><em>RadonMarket Academy, Centro di Formazione Professionale del Radon</em></span></p>
<p>The post <a href="https://www.radonmarketacademy.com/do-radon-levels-increase-with-the-age-of-a-building/">DO RADON LEVELS INCREASE WITH THE AGE OF A BUILDING?</a> appeared first on <a href="https://www.radonmarketacademy.com">RadonMarket Academy in English</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://www.radonmarketacademy.com/do-radon-levels-increase-with-the-age-of-a-building/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>HOW TO KNOW IF A RADON MITIGATION SYSTEM IS WORKING PROPERLY?</title>
		<link>https://www.radonmarketacademy.com/how-to-know-if-a-radon-mitigation-system-is-working-properly/</link>
					<comments>https://www.radonmarketacademy.com/how-to-know-if-a-radon-mitigation-system-is-working-properly/#respond</comments>
		
		<dc:creator><![CDATA[]]></dc:creator>
		<pubDate>Wed, 12 Jan 2022 13:24:47 +0000</pubDate>
				<category><![CDATA[○ Radon Short Articles]]></category>
		<category><![CDATA[RADON ARTICLES]]></category>
		<category><![CDATA[Micro Manometer]]></category>
		<category><![CDATA[Radon Mitigation]]></category>
		<category><![CDATA[RadonAway]]></category>
		<guid isPermaLink="false">https://www.radonmarketacademy.com/?p=1774</guid>

					<description><![CDATA[<p>RADON SHORT ARTICLES: &#8220;HOW TO KNOW IF A RADON MITIGATION SYSTEM IS WORKING PROPERLY?&#8221; There are several methods to lower Radon levels in a building. The recommendation is always to prevent Radon from entering the house. In some cases, there is no choice rather than reduce Radon after it has entered. What is will not [&#8230;]</p>
<p>The post <a href="https://www.radonmarketacademy.com/how-to-know-if-a-radon-mitigation-system-is-working-properly/">HOW TO KNOW IF A RADON MITIGATION SYSTEM IS WORKING PROPERLY?</a> appeared first on <a href="https://www.radonmarketacademy.com">RadonMarket Academy in English</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><span style="font-size: 18pt; font-family: 'arial black', sans-serif;"><strong><a href="https://www.radonmarketacademy.com/it/category/articoli-sul-radon/radon-in-pillole/"><img loading="lazy" decoding="async" class="alignnone wp-image-2086" src="https://www.radonmarketacademy.com/it/wp-content/uploads/sites/3/2020/11/Radon-in-Pillole-300x130.png" alt="" width="50" height="22" /></a><br />
</strong></span><span style="font-size: 18pt; font-family: 'arial black', sans-serif;"><strong><span style="font-size: 14pt;">RADON SHORT ARTICLES: &#8220;HOW TO KNOW IF A RADON MITIGATION SYSTEM IS WORKING PROPERLY?&#8221;</span></strong></span></p>
<p style="text-align: justify;">There are several methods to lower Radon levels in a building. The recommendation is always to prevent Radon from entering the house. In some cases, there is no choice rather than reduce Radon after it has entered.</p>
<p style="text-align: justify;">What is will not change is that a Radon reduction system similar to any other system needs some occasional maintenance. It is recommended to look at the warning devices regularly and make sure the system is working correctly. Here are two common warning devices for Sub-slab Depressurization (SSD) systems:</p>
<p style="text-align: justify;"><img loading="lazy" decoding="async" class="alignnone size-medium wp-image-1765" src="https://www.radonmarketacademy.com/wp-content/uploads/2022/01/RadonAway_Manometer_Analouge_Radon_Market-284x300.png" alt="" width="284" height="300" srcset="https://www.radonmarketacademy.com/wp-content/uploads/2022/01/RadonAway_Manometer_Analouge_Radon_Market-284x300.png 284w, https://www.radonmarketacademy.com/wp-content/uploads/2022/01/RadonAway_Manometer_Analouge_Radon_Market.png 572w" sizes="(max-width: 284px) 100vw, 284px" /> <img loading="lazy" decoding="async" class="alignnone size-medium wp-image-1766" src="https://www.radonmarketacademy.com/wp-content/uploads/2022/01/Airflow-Alarm-1-300x300.jpg" alt="" width="300" height="300" srcset="https://www.radonmarketacademy.com/wp-content/uploads/2022/01/Airflow-Alarm-1-300x300.jpg 300w, https://www.radonmarketacademy.com/wp-content/uploads/2022/01/Airflow-Alarm-1-150x150.jpg 150w, https://www.radonmarketacademy.com/wp-content/uploads/2022/01/Airflow-Alarm-1.jpg 430w" sizes="(max-width: 300px) 100vw, 300px" /></p>
<p style="text-align: justify;"><em>Left: RadonAway Manometers      Right: RadonAway Air Flow Alarm</em></p>
<p style="text-align: justify;">Eventually, it may need to replace the fans. However, good quality Radon fans work from 5 to 10 years and even more.</p>
<p>&nbsp;</p>
<table width="620">
<tbody>
<tr>
<td width="620">📣  It is also a good idea to retest at least every two years to ensure that Radon levels remain low.</td>
</tr>
</tbody>
</table>
<hr />
<p style="text-align: justify;"><a href="https://www.radonmarket.com/it/radonmarket-mag/" target="_blank" rel="noopener noreferrer"><img loading="lazy" decoding="async" class="alignnone wp-image-1990 size-medium" src="https://www.radonmarketacademy.com/it/wp-content/uploads/sites/3/2020/10/RadonMarket-Mag-Logo-300x53.png" alt="" width="300" height="53" /></a><br />
<span style="color: #808080;"><em>RadonMarket Academy, Centro di Formazione Professionale del Radon</em></span></p>
<p>The post <a href="https://www.radonmarketacademy.com/how-to-know-if-a-radon-mitigation-system-is-working-properly/">HOW TO KNOW IF A RADON MITIGATION SYSTEM IS WORKING PROPERLY?</a> appeared first on <a href="https://www.radonmarketacademy.com">RadonMarket Academy in English</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://www.radonmarketacademy.com/how-to-know-if-a-radon-mitigation-system-is-working-properly/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>RADON AND PRESSURE DIFFERENTIALS</title>
		<link>https://www.radonmarketacademy.com/radon-and-pressure-differentials/</link>
					<comments>https://www.radonmarketacademy.com/radon-and-pressure-differentials/#respond</comments>
		
		<dc:creator><![CDATA[]]></dc:creator>
		<pubDate>Wed, 12 Jan 2022 12:57:59 +0000</pubDate>
				<category><![CDATA[○ Radon Mitigation]]></category>
		<category><![CDATA[RADON ARTICLES]]></category>
		<category><![CDATA[GM1-2]]></category>
		<category><![CDATA[Grab Sampler]]></category>
		<category><![CDATA[Micro Manometer]]></category>
		<category><![CDATA[Radon Mitigation]]></category>
		<category><![CDATA[RadonAway]]></category>
		<guid isPermaLink="false">https://www.radonmarketacademy.com/?p=1759</guid>

					<description><![CDATA[<p>Reza Hosseini, PhD &#8211; Managing Director at RadonMarket, R&#38;D Manager &#38; NRPP MFM Certified Radon Professional at Niton srl There are three main forces that cause Radon laden soil gas to enter buildings. We learned from the previous articles that these forces are: ✅ Stack effect or chimney effects, ✅ Soil pressure, and, ✅ HVAC [&#8230;]</p>
<p>The post <a href="https://www.radonmarketacademy.com/radon-and-pressure-differentials/">RADON AND PRESSURE DIFFERENTIALS</a> appeared first on <a href="https://www.radonmarketacademy.com">RadonMarket Academy in English</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p style="text-align: justify;"><a href="https://www.radonmarket.com/it/radonmarket-mag/" target="_blank" rel="noopener noreferrer"><img loading="lazy" decoding="async" class="alignnone wp-image-1990 size-medium" src="https://www.radonmarketacademy.com/it/wp-content/uploads/sites/3/2020/10/RadonMarket-Mag-Logo-300x53.png" alt="" width="300" height="53" /></a><br />
<span style="color: #808080;"><em>Reza Hosseini, PhD &#8211; Managing Director at RadonMarket, R&amp;D Manager &amp; NRPP MFM Certified Radon Professional at Niton srl</em></span><br />
<img loading="lazy" decoding="async" class="aligncenter wp-image-1764 size-large" src="https://www.radonmarketacademy.com/wp-content/uploads/2022/01/Radon_Differential_Pressure_Radon_Market-1024x414.png" alt="" width="1024" height="414" srcset="https://www.radonmarketacademy.com/wp-content/uploads/2022/01/Radon_Differential_Pressure_Radon_Market-1024x414.png 1024w, https://www.radonmarketacademy.com/wp-content/uploads/2022/01/Radon_Differential_Pressure_Radon_Market-300x121.png 300w, https://www.radonmarketacademy.com/wp-content/uploads/2022/01/Radon_Differential_Pressure_Radon_Market-768x311.png 768w, https://www.radonmarketacademy.com/wp-content/uploads/2022/01/Radon_Differential_Pressure_Radon_Market-1536x621.png 1536w, https://www.radonmarketacademy.com/wp-content/uploads/2022/01/Radon_Differential_Pressure_Radon_Market.png 2044w" sizes="(max-width: 1024px) 100vw, 1024px" />There are three main forces that cause Radon laden soil gas to enter buildings. We learned from the previous articles that these forces are:</p>
<p style="text-align: justify;">✅ Stack effect or chimney effects,<br />
✅ Soil pressure, and,<br />
✅ HVAC systems.</p>
<p style="text-align: justify;">Whether it is natural, like the stack effect, or introduced to the building by an unbalanced HVAC system, these forces change the balance and create pressure differentials between the outside air and the inside air. The pressure differentials between outside and inside then define the behavior of soil gas entry into the house. Hence we can say that the mechanism of Radon entry is all about pressure differentials.</p>
<p style="text-align: justify;">In this number of RadonMarket Mag, we examine this topic in more detail and see how the pressure differentials are measured.</p>
<p style="text-align: justify;">We could have three conditions for pressure differentials. The building could be in positive<sup>📣</sup>, negative, or neutral pressure with respect to the outside. Let&#8217;s start with a neutral pressure condition.</p>
<p style="text-align: justify;"><strong>✔️ </strong><strong>NEUTRAL PRESSURE<br />
</strong>When good communication to the outdoor air exists in the basement, like open windows and doors or other big openings, the differential pressure reduces significantly. Therefore, there is not much movement between inside air and the Radon laden soil gas.<br />
Open windows and doors significantly affect the differential pressure and also provide some dilution, which helps reduce the Radon level.</p>
<p><img loading="lazy" decoding="async" class="aligncenter wp-image-1761 size-large" src="https://www.radonmarketacademy.com/wp-content/uploads/2022/01/Radon_Differential_Pressure_Natural_Radon_Market-1024x820.png" alt="" width="1024" height="820" srcset="https://www.radonmarketacademy.com/wp-content/uploads/2022/01/Radon_Differential_Pressure_Natural_Radon_Market-1024x820.png 1024w, https://www.radonmarketacademy.com/wp-content/uploads/2022/01/Radon_Differential_Pressure_Natural_Radon_Market-300x240.png 300w, https://www.radonmarketacademy.com/wp-content/uploads/2022/01/Radon_Differential_Pressure_Natural_Radon_Market-768x615.png 768w, https://www.radonmarketacademy.com/wp-content/uploads/2022/01/Radon_Differential_Pressure_Natural_Radon_Market.png 1300w" sizes="(max-width: 1024px) 100vw, 1024px" /></p>
<p style="text-align: center;"><em>Radon &amp; Neutral Pressure</em></p>
<table width="620">
<tbody>
<tr>
<td width="620">📣 It is interesting to know that a positive pressure equal to a few thousandths of an inch of the water column is enough to draw Radon into the house.</td>
</tr>
</tbody>
</table>
<p style="text-align: justify;"><strong> </strong></p>
<p style="text-align: justify;"><strong>✔️ </strong><strong>NEGATIVE PRESSURE<br />
</strong>Most houses have negative pressure<sup>📣</sup><sup>, </sup>which means that the pressure inside the house is lower than the outside air pressure. Negative pressure inside the building creates a vacuum that draws the outside air, including the soil gas, into the house. The negative pressure and the indoor Radon level are directly correlated. Higher negative pressure cause higher indoor Radon level<sup>🔔</sup>, and by decreasing the negative pressure, the indoor Radon level decrease.</p>
<p><img loading="lazy" decoding="async" class="aligncenter wp-image-1762 size-large" src="https://www.radonmarketacademy.com/wp-content/uploads/2022/01/Radon_Differential_Pressure_Negative_Radon_Market-1024x820.png" alt="" width="1024" height="820" srcset="https://www.radonmarketacademy.com/wp-content/uploads/2022/01/Radon_Differential_Pressure_Negative_Radon_Market-1024x820.png 1024w, https://www.radonmarketacademy.com/wp-content/uploads/2022/01/Radon_Differential_Pressure_Negative_Radon_Market-300x240.png 300w, https://www.radonmarketacademy.com/wp-content/uploads/2022/01/Radon_Differential_Pressure_Negative_Radon_Market-768x615.png 768w, https://www.radonmarketacademy.com/wp-content/uploads/2022/01/Radon_Differential_Pressure_Negative_Radon_Market.png 1300w" sizes="(max-width: 1024px) 100vw, 1024px" /></p>
<p style="text-align: center;"><em>Radon &amp; Negative Pressure</em></p>
<table width="620">
<tbody>
<tr>
<td width="620">📣 Some rare new homes may have systems to pressure the building positively.</td>
</tr>
</tbody>
</table>
<p style="text-align: justify;">A house in a negative pressure can suck air directly beneath it and generally up to 10 meters around its perimeter. This area could become even larger when the soil gas beneath the house&#8217;s perimeter cannot find a connection to the outside. For example, when around the building is covered by asphalt. Radon comes from the foundation, mostly (NOT Always!), there would be a higher Radon level in the basement. However, there is no predictable ratio between the basement and upper floors.</p>
<table width="620">
<tbody>
<tr>
<td width="620">🔔 Even with the negative pressure, the source (i.e., Radon in the soil gas) and the pathway are still needed to have Radon in the house!.</td>
</tr>
</tbody>
</table>
<p style="text-align: justify;"><strong>✔️ </strong><strong>POSITIVE PRESSURE<br />
</strong>When air blows from outside into the house creates positive pressure. The positive pressure pushes the soil gas back and does not let Radon comes inside. In this case, besides retarding the soil gas entry, it also provides some dilution. It is more common to see positive pressure in large buildings or houses equipped with swamp coolers.</p>
<p><img loading="lazy" decoding="async" class="aligncenter wp-image-1763 size-large" src="https://www.radonmarketacademy.com/wp-content/uploads/2022/01/Radon_Differential_Pressure_Positive_Radon_Market-1024x820.png" alt="" width="1024" height="820" srcset="https://www.radonmarketacademy.com/wp-content/uploads/2022/01/Radon_Differential_Pressure_Positive_Radon_Market-1024x820.png 1024w, https://www.radonmarketacademy.com/wp-content/uploads/2022/01/Radon_Differential_Pressure_Positive_Radon_Market-300x240.png 300w, https://www.radonmarketacademy.com/wp-content/uploads/2022/01/Radon_Differential_Pressure_Positive_Radon_Market-768x615.png 768w, https://www.radonmarketacademy.com/wp-content/uploads/2022/01/Radon_Differential_Pressure_Positive_Radon_Market.png 1300w" sizes="(max-width: 1024px) 100vw, 1024px" /></p>
<p style="text-align: center;"><em>Radon &amp; Positive Pressure</em></p>
<p style="text-align: justify;"><strong> </strong></p>
<p style="text-align: justify;"><strong> </strong></p>
<p style="text-align: justify;"><strong>🤷</strong> <strong>How to measure pressure differentials?<br />
</strong>➡️ Digital micromanometer<br />
They measure the pressure difference between two ports on the instrument.</p>
<p style="text-align: justify;">➡️ Smoke Bottles<br />
The smoke only shows the direction of airflow and does not provide a quantitative result. However, they are easy and very quick to use.</p>
<p style="text-align: justify;">➡️ GM 1-2<br />
The RadonAway GM 1-2 is a one-of-a-kind diagnostic aid designed specifically for the needs of Radon mitigation professionals. It is equipped with both a micro manometer and a grab sampler. The Radon grab sampler feature is the perfect diagnostic tool to assist in finding Radon sources, and the micro manometer measures pressure field extension.</p>
<p style="text-align: justify;"><em>RadonAway GM 1-2</em> <em>Radon Grab Sampler/Micro Manometer </em></p>
<table width="620">
<tbody>
<tr>
<td width="620">🗨️ In the future, we will talk about the effect of outdoor air, building height, and other parameters on pressure differentials, and we will learn about the concept of NPP (Neutral Pressure Plane). So do not miss the new numbers of RadonMarket Mag.</td>
</tr>
</tbody>
</table>
<p>The post <a href="https://www.radonmarketacademy.com/radon-and-pressure-differentials/">RADON AND PRESSURE DIFFERENTIALS</a> appeared first on <a href="https://www.radonmarketacademy.com">RadonMarket Academy in English</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://www.radonmarketacademy.com/radon-and-pressure-differentials/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>RADON REGULATION IN UNITED STATES OF AMERICA</title>
		<link>https://www.radonmarketacademy.com/radon-regulation-in-united-states-of-america/</link>
					<comments>https://www.radonmarketacademy.com/radon-regulation-in-united-states-of-america/#respond</comments>
		
		<dc:creator><![CDATA[]]></dc:creator>
		<pubDate>Thu, 11 Nov 2021 00:17:52 +0000</pubDate>
				<category><![CDATA[○ Radon Short Articles]]></category>
		<category><![CDATA[RADON ARTICLES]]></category>
		<guid isPermaLink="false">https://www.radonmarketacademy.com/?p=1641</guid>

					<description><![CDATA[<p>RADON SHORT ARTICLES: &#8220;RADON REGULATION IN UNITED STATES OF AMERICA&#8221; NEGLI STATI UNITI ✔ Limite di concentrazione pari a 4 pCi/l (corrispondente a circa 150 Bq/m3). ✔ Azioni di mitigazioni raccomandate anche in caso di superamento del valore di concentrazione di 2 pCi/l (corrispondente a circa 75 Bq/m3). ✔ Emanazione di normative tecniche, standard riconosciuti [&#8230;]</p>
<p>The post <a href="https://www.radonmarketacademy.com/radon-regulation-in-united-states-of-america/">RADON REGULATION IN UNITED STATES OF AMERICA</a> appeared first on <a href="https://www.radonmarketacademy.com">RadonMarket Academy in English</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><span style="font-size: 18pt; font-family: 'arial black', sans-serif;"><strong><a href="https://www.radonmarketacademy.com/it/category/articoli-sul-radon/radon-in-pillole/"><img loading="lazy" decoding="async" class="alignnone wp-image-2086" src="https://www.radonmarketacademy.com/it/wp-content/uploads/sites/3/2020/11/Radon-in-Pillole-300x130.png" alt="" width="50" height="22" /></a><br />
</strong></span><span style="font-size: 18pt; font-family: 'arial black', sans-serif;"><strong><span style="font-size: 14pt;">RADON SHORT ARTICLES: &#8220;RADON REGULATION IN UNITED STATES OF AMERICA&#8221;</span></strong></span></p>
<p><span style="font-size: 18pt; font-family: 'arial black', sans-serif;"><strong><span style="font-size: 14pt;"><img loading="lazy" decoding="async" class="alignnone wp-image-2558 size-full" src="https://www.radonmarketacademy.com/it/wp-content/uploads/sites/3/2021/08/National-Radon-Profeciency-Program.png" alt="" width="700" height="228" /></span></strong></span></p>
<p><strong>NEGLI STATI UNITI</strong></p>
<p>✔ Limite di concentrazione pari a 4 pCi/l (corrispondente a circa 150 Bq/m<sup>3</sup>).</p>
<p>✔ Azioni di mitigazioni raccomandate anche in caso di superamento del valore di concentrazione di 2 pCi/l (corrispondente a circa 75 Bq/m<sup>3</sup>).</p>
<p>✔ Emanazione di normative tecniche, standard riconosciuti (ASTM), guide per cittadini e professionisti.</p>
<p>✔ Istituito un sistema di qualificazione dei Professionisti del Radon (NRPP), che prevede la frequentazione di corsi, il superamento di esami, la formazione continua, e l’onere di dover dimostrare di attuare il Programma di Assicurazione della Qualità (tarature, prove di affidabilità, …).</p>
<p>RadonMarket  (Niton srl)  è la prima ed unica società in Italia che si avvale, per i rilievi Radon, di professionisti certificati dal National Radon Proficiency Program (NRPP) degli Stati Uniti.</p>
<p style="text-align: center;"><a href="https://nrpp.info/listings/bl-12588.html">Gianluca Troiano</a>                                  <a href="https://nrpp.info/listings/bl-12677.html">Reza Hosseini</a></p>
<hr />
<p style="text-align: justify;"><a href="https://www.radonmarket.com/it/radonmarket-mag/" target="_blank" rel="noopener noreferrer"><img loading="lazy" decoding="async" class="alignnone wp-image-1990 size-medium" src="https://www.radonmarketacademy.com/it/wp-content/uploads/sites/3/2020/10/RadonMarket-Mag-Logo-300x53.png" alt="" width="300" height="53" /></a><br />
<span style="color: #808080;"><em>RadonMarket Academy, Centro di Formazione Professionale del Radon</em></span></p>
<p>The post <a href="https://www.radonmarketacademy.com/radon-regulation-in-united-states-of-america/">RADON REGULATION IN UNITED STATES OF AMERICA</a> appeared first on <a href="https://www.radonmarketacademy.com">RadonMarket Academy in English</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://www.radonmarketacademy.com/radon-regulation-in-united-states-of-america/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>WHAT ARE THE EFFECTS OF SNOW, RAIN &#038; FROST ON RADON?</title>
		<link>https://www.radonmarketacademy.com/what-are-the-effects-of-snow-rain-frost-on-radon/</link>
					<comments>https://www.radonmarketacademy.com/what-are-the-effects-of-snow-rain-frost-on-radon/#respond</comments>
		
		<dc:creator><![CDATA[]]></dc:creator>
		<pubDate>Thu, 11 Nov 2021 00:12:41 +0000</pubDate>
				<category><![CDATA[○ Radon Short Articles]]></category>
		<category><![CDATA[RADON ARTICLES]]></category>
		<guid isPermaLink="false">https://www.radonmarketacademy.com/?p=1639</guid>

					<description><![CDATA[<p>RADON SHORT ARTICLES: &#8220;WHAT ARE THE EFFECTS OF SNOW, RAIN &#38; FROST ON RADON?&#8221; 👁‍L’effetto è quello di incrementare la differenza di pressione negativa tra l’interno dell’edificio ed il suolo, incrementando quindi le forze convettive e favorendo l’ingresso del Radon. ☔ La pioggia può creare una sorta di cappuccio sul suolo che esercita sulla stesso [&#8230;]</p>
<p>The post <a href="https://www.radonmarketacademy.com/what-are-the-effects-of-snow-rain-frost-on-radon/">WHAT ARE THE EFFECTS OF SNOW, RAIN &#038; FROST ON RADON?</a> appeared first on <a href="https://www.radonmarketacademy.com">RadonMarket Academy in English</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><span style="font-size: 18pt; font-family: 'arial black', sans-serif;"><strong><a href="https://www.radonmarketacademy.com/it/category/articoli-sul-radon/radon-in-pillole/"><img loading="lazy" decoding="async" class="alignnone wp-image-2086" src="https://www.radonmarketacademy.com/it/wp-content/uploads/sites/3/2020/11/Radon-in-Pillole-300x130.png" alt="" width="50" height="22" /></a></strong></span></p>
<p><span style="font-size: 18pt; font-family: 'arial black', sans-serif;"><strong><span style="font-size: 14pt;">RADON SHORT ARTICLES: &#8220;WHAT ARE THE EFFECTS OF SNOW, RAIN &amp; FROST ON RADON?&#8221;</span></strong></span></p>
<p><span style="font-size: 18pt; font-family: 'arial black', sans-serif;"><strong><span style="font-size: 14pt;"><img loading="lazy" decoding="async" class="aligncenter wp-image-2554 size-full" src="https://www.radonmarketacademy.com/it/wp-content/uploads/sites/3/2021/07/In-che-modo-neve-pioggia-e-gelo-influenzano-il-Radon-1.jpg" alt="" width="1423" height="656" /></span></strong></span></p>
<table style="border-collapse: collapse; width: 100%;">
<tbody>
<tr>
<td style="width: 100%;">👁‍L’effetto è quello di incrementare la differenza di pressione negativa tra l’interno dell’edificio ed il suolo, incrementando quindi le forze convettive e favorendo l’ingresso del Radon.</td>
</tr>
</tbody>
</table>
<p style="text-align: justify;">☔ La pioggia può creare una sorta di cappuccio sul suolo che esercita sulla stesso una pressione.</p>
<p style="text-align: justify;">❄ Come per la pioggia, l’effetto è quello di una sorta di cappuccio sul suolo, ma che può essere esteso a superfici molto grandi intorno all’edificio, con l’effetto di una capacità dello stesso di «aspirare Radon» per un raggio anche di 10 metri oltre il suo perimetro.</p>
<p style="text-align: justify;">🗯 L’asfalto intorno all’edificio può produrre effetti analoghi.</p>
<hr />
<p><a href="https://www.radonmarket.com/it/radonmarket-mag/" target="_blank" rel="noopener noreferrer"><img loading="lazy" decoding="async" class="alignnone wp-image-1990 size-medium" src="https://www.radonmarketacademy.com/it/wp-content/uploads/sites/3/2020/10/RadonMarket-Mag-Logo-300x53.png" alt="" width="300" height="53" /></a></p>
<p><span style="color: #808080;"><em>RadonMarket Academy, Centro di Formazione Professionale del Radon</em></span></p>
<p>The post <a href="https://www.radonmarketacademy.com/what-are-the-effects-of-snow-rain-frost-on-radon/">WHAT ARE THE EFFECTS OF SNOW, RAIN &#038; FROST ON RADON?</a> appeared first on <a href="https://www.radonmarketacademy.com">RadonMarket Academy in English</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://www.radonmarketacademy.com/what-are-the-effects-of-snow-rain-frost-on-radon/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>METHODS TO REDUCE THE CONCENTRATION OF RADON ACTIVITIES IN WATER</title>
		<link>https://www.radonmarketacademy.com/methods-to-reduce-the-concentration-of-radon-activities-in-water/</link>
					<comments>https://www.radonmarketacademy.com/methods-to-reduce-the-concentration-of-radon-activities-in-water/#respond</comments>
		
		<dc:creator><![CDATA[]]></dc:creator>
		<pubDate>Wed, 10 Nov 2021 23:55:34 +0000</pubDate>
				<category><![CDATA[○ Radon Mitigation]]></category>
		<category><![CDATA[RADON ARTICLES]]></category>
		<category><![CDATA[Radon in Water]]></category>
		<category><![CDATA[Radon Mitigation]]></category>
		<guid isPermaLink="false">https://www.radonmarketacademy.com/?p=1632</guid>

					<description><![CDATA[<p>Reza Hosseini, PhD &#8211; Managing Director at RadonMarket, R&#38;D Manager &#38; NRPP MFM Certified Radon Professional at Niton srl In the last number of RadonMarket Mag we have talked about Radon in water. We have seen &#8220;How does Radon initially dissolve in water?&#8221;, &#8220;How to evaluate the contribution of water in the increase of Radon [&#8230;]</p>
<p>The post <a href="https://www.radonmarketacademy.com/methods-to-reduce-the-concentration-of-radon-activities-in-water/">METHODS TO REDUCE THE CONCENTRATION OF RADON ACTIVITIES IN WATER</a> appeared first on <a href="https://www.radonmarketacademy.com">RadonMarket Academy in English</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><a href="https://www.radonmarket.com/it/radonmarket-mag/" target="_blank" rel="noopener noreferrer"><img loading="lazy" decoding="async" class="alignnone wp-image-1990 size-medium" src="https://www.radonmarketacademy.com/it/wp-content/uploads/sites/3/2020/10/RadonMarket-Mag-Logo-300x53.png" alt="" width="300" height="53" /></a><br />
<span style="color: #808080;"><em>Reza Hosseini, PhD &#8211; Managing Director at RadonMarket, R&amp;D Manager &amp; NRPP MFM Certified Radon Professional at Niton srl</em></span></p>
<p style="text-align: justify;">In the last number of <a href="https://www.radonmarket.com/it/radonmarket-mag/">RadonMarket Mag</a> we have talked about Radon in water. We have seen &#8220;How does Radon initially dissolve in water?&#8221;, &#8220;How to evaluate the contribution of water in the increase of Radon in the air?&#8221; and &#8220;What to keep in mind when dealing with the Radon problem in water?&#8221;. In this article, we continue our discussion, and we will review the most common methods to reduce the concentration of Radon activity in water. If you missed the previous number of RadonMarket Mag (<a href="https://www.radonmarket.com/it/radonmarket-mag/#dearflip-df_15040/1/">n° 14</a>), please read it before starting this one.</p>
<p><em><img loading="lazy" decoding="async" class="aligncenter wp-image-2548 size-large" src="https://www.radonmarketacademy.com/it/wp-content/uploads/sites/3/2021/07/METODI-PER-RIDURRE-LA-CONCENTRAZIONE-DI-ATTIVITA-DI-RADON-IN-ACQUA-RadonMarket-Mag-1024x667.jpg" alt="" width="1024" height="667" /></em></p>
<p style="text-align: center;"><em>Radon presente nell’acqua di pozzo che contribuisce al livello generale di Radon indoor</em></p>
<p>Practically there are three ways to reduce Radon in water:</p>
<p>I. Surface and Decay Storages<br />
II. Carbon Absorption tanks<br />
III. Aeration systems</p>
<p><strong>I. Surface and Decay Storages<br />
</strong>On the contrary of well water, surface water typically does not present a Radon in water concern. This is because there is enough residence time for Radon to off-gas and gradually dilute in an open environment as well as decay to Radon Decay Products (RDPs) product <sup>🔔</sup>.</p>
<p>&nbsp;</p>
<table style="border-collapse: collapse; width: 100%;">
<tbody>
<tr>
<td style="width: 100%;">🔔 Ingestion of the RDPs not considered to be a significant health concern.<br />
Se non ricordi quali sono gli effetti sulla salute dovuti alla presenza di Radon, guarda questo <a href="https://www.radonmarketacademy.com/it/1548">Video corso gratuito su RadonMarket Academy</a>.<img loading="lazy" decoding="async" class="size-medium wp-image-1562 aligncenter" src="https://www.radonmarketacademy.com/it/wp-content/uploads/sites/3/2020/01/Il-Radon-e-i-suoi-Effetti-sulla-Salute-300x157.png" alt="" width="300" height="157" /></td>
</tr>
</tbody>
</table>
<p style="text-align: justify;">Similarly, storing well water in a reservoir could reduce the Radon in water and consider as a mitigation technique. In many public water supplies, groundwater is pumped to the atmospheric storage before it pumps again to consumers&#8217; houses. The private wells usually do not have a reservoir tank, and putting one is expensive and impractical. Hence, storage might not be a solution to mitigate Radon in water for individual wells.<br />
As a general rule, homes at the far ends of the distribution network can have less Radon as more residence time allows Radon to decay to RDPs. On the other hand, when water usage goes up, the residence time goes down, and consequently, there is less time for Radon to decay.</p>
<p style="text-align: justify;"><strong>II. Carbon Absorption tanks<br />
</strong>Radon could adsorb onto activated charcoal due to physical adsorption or so-called physisorption. The fundamental interacting force of physisorption is Van der Waals <sup>🔔</sup>. The Charcoal Canisters for short-term Radon measurements are operated based on physisorption <sup>🔔🔔</sup>.</p>
<p>&nbsp;</p>
<table style="border-collapse: collapse; width: 100%; height: 428px;">
<tbody>
<tr style="height: 428px;">
<td style="width: 100%; height: 428px;">
<p style="text-align: justify;">🔔 If you are interested to know more about physisorption, read this article on <a href="https://en.wikipedia.org/wiki/Physisorption">Wikipedia</a>.</p>
<p style="text-align: justify;">🔔🔔 The charcoal canisters are 4-inch open-face canisters. They consist of a metal canister filled with activated charcoal that is held in place by a wire mesh screen and spring clip. The Radon gas and some of the progeny attach to the charcoal surface. At the end of the testing, the canister is sealed and returned to the laboratory for processing and analysis.</p>
<p style="text-align: justify;"><img loading="lazy" decoding="async" class="size-medium wp-image-2549 aligncenter" src="https://www.radonmarketacademy.com/it/wp-content/uploads/sites/3/2021/07/Charcoal-Canister-Radon-Short-Term-RadonMarket-300x300.jpg" alt="" width="300" height="300" /></p>
</td>
</tr>
</tbody>
</table>
<p style="text-align: justify;">Applying the same concept makes it possible to catch Radon in water by running the water through a larger tank fill with Granular Activated Charcoal (GAC). Remember that this is different from the small filters commonly put on the faucets to clean and improve water taste. For reducing Radon in water, the carbon tank should be big enough to support all the water usage of a house (except the water needed for gardening or use in open spaces). In addition, the tank should be installed at the entry point of the water supply.<br />
When Radon is absorbed onto the charcoal, it breaks down into RDPs, and the produced RDPs are retained inside the tank. This maintains the concentration gradient between the Radon in water and the surface of the charcoals. Therefore, it creates a sort of self-cleaning system, and Radon can adsorb onto charcoal forever. However, there is a critical issue preventing the unlimited usage of the carbon tank! If you have read our previous articles, it may not be difficult to guess what this preventing reason is?<br />
Clearly, the first reason could be clogging. Even though these systems have filters for removing the particles from the water, eventually, the dirt accumulates inside the tank, and the tank should be replaced. Still, the reason that may concern us more is the Gamma radiation!<br />
As Radon decays inside the tank, it releases alpha, beta, and Gamma. The alpha and beta can not get out of the tank, but gamma certainty can. By accumulating the RDPs inside the tank, gamma emissions increase and become more significant <sup>🗯</sup>.  Of course, no one wants to keep a tank with radioactive material emitting Gamma radiation inside their house. Hence, carbon tanks are typically replaced yearly to prevent this issue.</p>
<p>&nbsp;</p>
<table style="border-collapse: collapse; width: 100%;">
<tbody>
<tr>
<td style="width: 100%;">
<p style="text-align: justify;">🗯 The amount of Gamma that could be emitted from these tanks is 1 mR/hr per 370 Bq/L in water (10000 pCi/L in water). Hence, these systems are not generally recommended for Radon in water with a concentration greater than 370-740 Bq/L (10-20000 pCi/L in water) as a means to limit Gamma emission.</p>
<p style="text-align: justify;">🤷‍ What happens when carbon tanks are taken out of service?<br />
<span style="font-family: inherit; font-size: inherit;">After being taken out of service, the short-lived decay products inside the tank are broken down quickly, and the gamma emission from them decreases rapidly. But there will still be gamma emission from Lead (</span><sup style="font-family: inherit;">210</sup><span style="font-family: inherit; font-size: inherit;">Pb) with a half-life of 22.3 years, which needs further disposal considerations.</span></p>
</td>
</tr>
</tbody>
</table>
<p style="text-align: justify;">Besides the complication that this method introduces, it is a valid technique for reducing the Radon in water. Moreover, there are also other advantages of using carbon, like reducing the odor and improving water taste.</p>
<p><strong>III. Aeration systems<br />
</strong>We have seen that the dissolved Radon easily gets out of the water and becomes a health risk when we use showers. So why not apply the same mechanism to reduce the Radon in water? This is exactly what happens in an aeration system.</p>
<p>In the aeration method, water from the well is sprayed into a tank, similar to a mini shower. At the same time, or by bellowing air with a pump or by making air bubbles inside the tank, Radon strips out from the water. Then the released  Radon exhaust out of the house.</p>
<p style="text-align: justify;">Aeration system also has their own limitations.</p>
<p style="text-align: justify;">🔵 Like an Active Soil Depressurization (ASD), the discharge point for an aeration system should be located in a proper place to prevent exposing people to high Radon concentrations. In addition, because of the high humidity of the exhausted air from an aeration system, special attention is needed for the possible condensation problems.<br />
🔵 On the contrary to carbon absorption, the aeration method puts water at atmospheric pressure. Therefore, an additional pressure tank and pump are needed to distribute water throughout the building.<br />
🔵 The biggest concern in aeration systems is water quality. Blowing air through water could introduce bacteria and other organisms. For this reason, the source of the incoming air should be clean, and the air should pass through proper filters before contacting with water. In order to improve the water quality, especially when water is not in use continuously, an aeration system may also be equipped with a pre or post-disinfection with chlorine or post-disinfection with ultra-violet light systems.</p>
<p>&nbsp;</p>
<table style="border-collapse: collapse; width: 100%;">
<tbody>
<tr>
<td style="width: 100%;">☢ As a final comment, we can say that reducing Radon in water is a much expensive and complex project compared to a standard ASD system. Besides lowering the Radon, special attention needs to guarantee the quality of the drinking water. Therefore, when Radon in water is a concern, it is always recommended to ask for help from both Radon and water quality specialists.</td>
</tr>
</tbody>
</table>
<p>The post <a href="https://www.radonmarketacademy.com/methods-to-reduce-the-concentration-of-radon-activities-in-water/">METHODS TO REDUCE THE CONCENTRATION OF RADON ACTIVITIES IN WATER</a> appeared first on <a href="https://www.radonmarketacademy.com">RadonMarket Academy in English</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://www.radonmarketacademy.com/methods-to-reduce-the-concentration-of-radon-activities-in-water/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
	</channel>
</rss>
